It is applicable to the desalination of municipal water, groundwater with salt concentration less than 1000ppm. It can be widely used in pure water preparation and related industries.
Model | Active Membrane Area ft2(m2) | Permeate Flow GPD(T/D) | Stable Rejection Rate (%) |
XLP-4040HR | 85(7.9) | 2000(7.6) | 99.3 |
Concentration of Solution (NaCl) | Temperature(℃) | pH Value > | Operating Pressure psi(MPa) | Recovery Rate(%) |
500ppm | 25 | 7.5-8 | 100(0.69) | 15 |
Notes: The permeate flow of single membrane element may vary with in ±15%.
Operating Limits and Conditions of Membrane Element:
Max.Working Pressure | 600 psi(4.14MPa) |
Max. FeedWater Temperature | 45 ℃ |
Max. Feed Water Flow | 3.6m3/h |
Max. FeedWaterSDI15 | 5.0 |
Free Chlorine Concentration of FeedWater | 0.1mg/L |
pHRange of FeedWaterDuring Continuous Operation | 2-11 |
pHRange of FeedWaterDuring Chemical Cleaning | 1-13 |
Max. Pressure Drop of Single Membrane Element | 15psi(0.1Mpa) |