Groundwater treatment for municipal drinking system in Tunisia
1.Project Brief
Due to the lack of fresh water resources, Tunisia mainly solves the water problem by digging underground water.However, due to the excessive collection of groundwater, the salinity of water quality has increased significantly, so it is necessary to desalinate the collected groundwater before it enters the municipal pipeline network.
2.Technological Process
Ground water—MMF—ACF—Sedimentation—Resin softening tank—Cartrige filter—RO
3.System Quick Facts
Element Model | Permeate Flux | Recovery | Operating Pressure | Permeate Flow | Pressure Vessel Array |
BW-8040 | 23.5LMH | 75% | 1.2-1.5MPa | 105m³/h | 12:8 (6 cores),2series |
4.System Operation Data
Date | Operating Pressure | Permeate Flow | Recovery | Salt Rejection | Temperature |
2019.5 | 14bar | 215m³/h | 75.1% | 98.7% | 23℃ |
Welcome contact with us:
KeenSen Technology Co., Ltd. is specialized in aromatic polyamide Reverse Osmosis and Nanofiltration membrane elements of polyamide memebrane elements of R&D, production and service provider. If you need to learn more information about KeenSen "BW-8040" RO membrane element, do not hesitate to send e-mail to sales@keensen.com or add skype: Keensen01
Information about
Similar article ranking
- Boiler feedwater for petroleum industry in Pakistan
- Groundwater treatment for municipal drinking system in Tunisia
- Sea water desalination projects for petroleum industry in Australia
- Production water project for paper mill in Indonesia
- Waste water reuse project in Australia
- Reclaimed water project in Korean glass factory
- Production water supply system for food industry in Mexico
- Reclaimed water project for electronics industry in Malaysia
- Boiler feedwater for petroleum industry in Azerbaijan
- Boiler feedwater for thermoelectric in Thailand